CDCS PDF GUIDE & LATEST CDCS TEST PREPARATION

CDCS PDF Guide & Latest CDCS Test Preparation

CDCS PDF Guide & Latest CDCS Test Preparation

Blog Article

Tags: CDCS PDF Guide, Latest CDCS Test Preparation, CDCS Study Material, Exam Dumps CDCS Free, CDCS Testking

Someone asked, where is success? Then I tell you, success is in ExamsReviews. Select ExamsReviews is to choose success. ExamsReviews's EXIN CDCS exam training materials can help all candidates to pass the IT certification exam. Through the use of a lot of candidates, ExamsReviews's EXIN CDCS Exam Training materials is get a great response aroud candidates, and to establish a good reputation. This is turn out that select ExamsReviews's EXIN CDCS exam training materials is to choose success.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.
Topic 2
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.
Topic 3
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.

>> CDCS PDF Guide <<

Latest CDCS Test Preparation & CDCS Study Material

We are so sincere to provide a free trial version of our CDCS exam questions for you, just want you to find the best product for your own. We hope that you are making a choice based on understanding our CDCS study braindumps. And you will find that our CDCS training materials are so popular for their special advantages. Not only the content is always the latest, but also the displays are design carefully to cater to all kinds of study conditions. We will respect your decision. And our CDCS learning guide really wants to be your long-term partner.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q11-Q16):

NEW QUESTION # 11
What indicates the breaking capacity of a fuse or breaker?

  • A. The current at which the device will trip.
  • B. Mechanical strength of the casing of a fuse or breaker.
  • C. The maximum voltage, in case of an electrical surge, that the fuse or breaker can handle without being destroyed or causing an electric damaging arc.
  • D. The current that a fuse or breaker is able to interrupt without being destroyed or causing an electric damaging arc.

Answer: D

Explanation:
The breaking capacity of a fuse or breaker indicates the maximum current it can safely interrupt without being damaged or creating a dangerous arc. This value is crucial for ensuring that the device can handle fault conditions and prevent equipment damage or fire risks due to excessive current flow.
Detailed Explanation:
The breaking capacity, also known as the interrupting rating, ensures that the fuse or breaker can safely handle fault currents up to a specified limit. Exceeding this capacity could result in the device failing to interrupt the current, potentially causing hazardous conditions like electrical arcs.
EPI Data Center Specialist References:
EPI training underscores the importance of matching fuses and breakers with appropriate breaking capacities for the anticipated fault levels in data centers to ensure reliable and safe operation.


NEW QUESTION # 12
What is the minimum requirement for the power feeds to the building for a Rated-3 data center based on the ANSI/TIA-942 standard?

  • A. Two feeds coming from two different substations, one power company is not acceptable
  • B. Two feeds entering the data center building from one substation
  • C. One feed from one substation split over two separated distribution boards in separate rooms
  • D. Two feeds coming from two different substations, one power company is acceptable

Answer: D

Explanation:
The minimum requirement for power feeds to a Rated-3 data center according to ANSI/TIA-942 is to have two independent power feeds, which can come from two different substations provided by the same power company. This ensures redundancy and concurrent maintainability, as each feed can support the load independently during maintenance or failure of the other.
Detailed Explanation:
The separation by two substations ensures resilience in case of a localized outage or substation maintenance, aligning with Rated-3 requirements for uninterrupted operation. ANSI/TIA-942 permits these feeds from a single utility provider as long as they are supplied from distinct substations.
EPI Data Center Specialist References:
EPI underscores the importance of dual power feeds from separate substations for Rated-3 facilities, highlighting that the ability to draw from different substations aligns with redundancy requirements for high availability.


NEW QUESTION # 13
In order to save energy, you are going to install an automated system to switch off lights. What should be taken into consideration when installing such a system?

  • A. At all times, the levels should allow for security cameras to function properly.
  • B. It is not advisable to use such a system since it will reduce the lifetime of LED lighting.
  • C. The system should not be based on motion detection as the lights might suddenly switch off while staff is still at work.
  • D. Security guards should perform regular inspections verifying the system works.

Answer: A


NEW QUESTION # 14
The 'maximum exposed area' of the fire-rated glass is defined by the supplier as 3 sqm/32 sqft. The window area is 4 sqm/43 sqft.
What would be the best option?

  • A. Split the window in two equal parts fitted together with transparent silicon glue.
  • B. Do not use fire-rated glass due to the size limit and replace it with normal glass.
  • C. Split the window into parts smaller than specified as the maximum exposed area and ensure fire-rated frames are used.
  • D. Split the window in two equal parts using an aluminum frame.

Answer: C

Explanation:
When the window area exceeds the maximum exposed area specified for fire-rated glass, it is necessary to split the window into sections that comply with the fire rating requirements. This means creating smaller sections that are each within the 3 sqm/32 sqft limit and using fire-rated frames to ensure that the entire assembly meets fire safety standards. This approach maintains the fire-rated integrity of the glass, while allowing for larger window areas.
Detailed Explanation:
Fire-rated glass is designed to contain fire and prevent it from spreading. If the window exceeds the maximum exposed area defined by the supplier, the integrity of the fire-rated glass could be compromised. By dividing the window into compliant sections with fire-rated frames, you ensure that each pane performs as intended in the event of a fire. Fire-rated frames help maintain the fire resistance across the entire assembly, making this option the best for safety and compliance.
EPI Data Center Specialist References:
EPI recommends adhering strictly to fire safety standards, especially when using materials like fire-rated glass. The guidelines emphasize that modifications should always respect the manufacturer's specifications to ensure the system remains effective in containing and preventing the spread of fire.


NEW QUESTION # 15
An air-conditioner unit needs to be selected. Two types are available:
Unit-A has a Sensible Heat Ratio (SHR) of 0.7.
Unit-B has a Sensible Heat Ratio (SHR) of 0.9.
From an efficiency point of view, which one should be selected?

  • A. Unit B
  • B. Not relevant, as Sensible Heat Ratio is only specified for air-conditioner equipment to indicate the ratio between intake temperature and exhaust temperature.
  • C. Unit A
  • D. It does not matter, as the Sensible Heat Ratio has nothing to do with efficiency.

Answer: A

Explanation:
From an efficiency standpoint, Unit B with a Sensible Heat Ratio (SHR) of 0.9 is preferable. A higher SHR indicates that a greater proportion of the air conditioner's capacity is dedicated to sensible cooling (temperature reduction) rather than latent cooling (moisture removal). In data centers, sensible cooling is more critical since IT equipment primarily generates heat without adding significant moisture.
Detailed Explanation:
An SHR of 0.9 means that 90% of the cooling capacity is used for sensible cooling, which is more efficient for environments like data centers where humidity control is typically less of a concern. Opting for an air conditioner with a higher SHR ensures that most of the cooling energy is focused on temperature reduction, making Unit B more efficient in this scenario.
EPI Data Center Specialist References:
EPI data center best practices recommend choosing cooling units with higher SHR values in data centers, as they better match the cooling needs of IT equipment. High SHR units improve cooling efficiency by concentrating on sensible heat removal, which is vital for maintaining the optimal thermal environment.


NEW QUESTION # 16
......

ExamsReviews provide a good after-sales service for all customers. If you choose to purchase ExamsReviews products, ExamsReviews will provide you with online service for 24 hours a day and one year free update service, which timely inform you the latest exam information to let you have a fully preparation. We can let you spend a small amount of time and money and pass the IT certification exam at the same time. Selecting the products of ExamsReviews to help you pass your first time EXIN Certification CDCS Exam is very cost-effective.

Latest CDCS Test Preparation: https://www.examsreviews.com/CDCS-pass4sure-exam-review.html

Report this page